Construction [💾save.pdf]
Conductor |
Material |
BC |
Diameter |
1.29mm ± 0.02 mm |
|
Wire Gauge |
16 AWG |
|
Insulation |
Material |
FPE |
Diameter Diameter |
5.72 mm ± 0.2 mm |
|
AL Foil |
Construction |
With Foil |
Material |
AP |
|
Width |
22 mm |
|
thickness |
> 0.024 mm |
|
Overlap Rate |
≥ 20% |
|
Braid |
Material |
AL |
Diameterr |
0.12 mm |
|
Braid Coverage |
60% - 98% |
|
Jacket |
Material |
PVC |
Diameter |
8.1 mm ± 0.5 mm |
Packing
Package length |
100m / 300m / 500m |
Customized |
|
Box type |
Ordinary / Waterproof |
Customized optional |
Test Data
Dielectric Strength |
Not breakdown with 2kV DC for 1 min |
Sheath Strength |
Not breakdown with 3kV |
Characteristic Resistance |
75Ω ± 5Ω |
Insulation Resistance |
5000MΩ/km |
Elongation at Break (Wire) |
≥15% |
Elongation at Break (Sheath) |
≥150% |
Low Temperature Bending |
Not cracked |
Thermal Shock |
Not cracked |
Operating Temperature |
–20°C to +60°C (–4°F to 140°F) |
Storage Temperature |
–10°C to +40°C (14°F to 104°F) |
Certifications and Standards
Certification |
CPR Eca |
Executive Standards |
Q/DXJ 194-2020 |
Technical Test [Attenuation @68°F(20°C)]
Frequency(MHZ) |
Maximum(dB/100ft) |
Maximum(dB/100m) |
5 |
0.47 |
1.54 |
55 |
1.25 |
4.1 |
211 |
2.36 |
7.74 |
250 |
2.56 |
8.4 |
270 |
2.68 |
8.78 |
300 |
2.82 |
9.25 |
330 |
2.96 |
9.72 |
350 |
3.05 |
10.01 |
400 |
3.27 |
10.73 |
450 |
3.46 |
11.35 |
500 |
3.67 |
12.04 |
550 |
3.85 |
12.63 |
600 |
4.05 |
13.28 |
1000 |
5.32 |
17.45 |
1200 |
5.87 |
19.23 |
1750 |
7.05 |
23.10 |
2150 |
7.79 |
25.54 |