Construction [💾save.pdf]
Conductor |
Material |
OFC |
Diameter |
0.51 mm ± 0.02 mm |
|
Wire Gauge |
24 AWG |
|
Insulation |
Material |
FPE |
Diameter Diameter |
3.0 mm ± 0.3 mm |
|
AL Foil |
Construction |
With Foil |
Material |
APG |
|
Width |
12 mm |
|
thickness |
> 0.024 mm |
|
Overlap Rate |
≥ 30% |
|
Braid |
Material |
OFC |
Diameterr |
0.12 mm |
|
Braid Coverage |
90% - 98% |
|
Jacket |
Material |
PVC |
Diameter |
5.0 mm ± 0.2 mm |
Packing
Package length |
10m / 30m / 50m |
Customized |
|
Box type |
Ordinary / Waterproof / Trolley |
Customized optional |
Test Data
Dielectric Strength |
Not breakdown with 2kV DC for 1 min |
Sheath Strength |
Not breakdown with 3kV |
Characteristic Resistance |
75Ω ± 5Ω |
Insulation Resistance |
5000MΩ/km |
Elongation at Break (Wire) |
≥15% |
Elongation at Break (Sheath) |
≥150% |
Low Temperature Bending |
Not cracked |
Thermal Shock |
Not cracked |
Operating Temperature |
–20°C to +60°C (–4°F to 140°F) |
Storage Temperature |
–10°C to +40°C (14°F to 104°F) |
Certifications and Standards
Certification |
CPR Eca |
Executive Standards |
Q/DXJ 194-2020 |
Technical Test [Attenuation @68°F(20°C)]
Frequency(MHZ) |
Maximum(dB/100ft) |
Maximum(dB/100m) |
5 |
2.88 |
9.60 |
100 |
4.13 |
13.75 |
300 |
7.29 |
24.27 |
500 |
9.53 |
31.74 |
100 |
13.80 |
45.95 |